Three
Phase Electrical Actuator - Rotary |
|
|
|
|
SPECIFICATIONS |
“Cair”
offers three phase Quarter turn electrical actuator
for valves and engineering use. |
Enclosure |
» |
Standard enclosure to water jet
proof will water tight proof IP 67.NEMA 4&6 |
|
TOP |
Motor |
» |
Squirrel cage motor is of encapsulated
type, on high stall torque and low inherent
force for seating & unseating of valves.
All motors are integrated with build-in thermal
protection. |
|
Terminal
Connection & Wiring |
» |
Terminal connections are of "WAGO"
push on type, making wiring connection very
easy & without fuss. Electrical wiring circuit
is standardized for single & three phase
voltage. Addition termination is available on
request. |
|
Internal
Components Arrangement |
» |
Internal mechanical and electrical
components are design in modular mounting arrangement,
and can be easily remove for maintenance purposes.
Additional optional accessories are also possible. |
|
Limit
Switches |
» |
A pair of limit switches are
activated by means of simple, reliable &
adjustable cam plates, mounted directly onto,
and driven by center column. The unique cam
plate design does not allow over travel of limit
switches. |
|
Torque
Switches |
» |
Electric actuators on 100 N •
m and above, are install with torque switches
for over-load protection. |
|
Heater |
» |
For prevention of condensation
due to weather& temperature changes, an
d also keeps internal components clean &
dry, a 20 Walt space heater is provided inside
all the electric actuators. |
|
Self
Locking Mechanism |
» |
Because of the worm gear design
system, all the electric actuators are self-locking. |
|
TOP |
Handwheel |
» |
Correct size of handwheel on
the electric actuator ensure adequate strength
for safe and efficient emergency operation. |
|
Manual
Over-Ride |
» |
Engage by pulling the lever &
turning the handwheel. Lever is auto declutch
when power supply is switch on, and hand wheel
does not turn as extra safety feature. |
|
Visual
Position Indicator |
» |
The visual position indicator
is directly mounted onto the center drive column
to provide the visual position of the valve. |
|
End
Stoppers |
» |
1 each for open & close position
(adjustable), are for over travel protection. |
|
Potentiometer-Otional |
» |
Is available on request, is to
provide & transmit remote indication of
valve position. |
|
Mounting
& Adaptation |
» |
Bottom flange mounting dimension
conform to ISO 5211. Aadaptor drive bushing
is provided for every electric actuator. Is
removable and for machining to suite valve stem
size. |
|
TOP |
Performance |
Type |
Max
output Torque |
Operating
Time 60/50 Hz |
Max
Stem Dia. |
Motor
30 Min. Class F |
Rated
Current (mA) |
Number
Of Handle Turn |
Weight
(Kg) |
1 Phase |
3 Phase |
Kg • m |
90 Deg. |
mm |
W |
110V |
220V |
380V |
440V |
ATQ03* |
3 |
14/17 |
14 |
10 |
650 |
300 |
N/A |
N/A |
8.5 |
6 |
ATQ04* |
4 |
14/17 |
14 |
10 |
650 |
300 |
N/A |
N/A |
8.5 |
6 |
ATQ06* |
6 |
14/17 |
22 |
15 |
1250 |
400 |
N/A |
N/A |
8.5 |
9 |
ATQ09* |
9 |
14/17 |
22 |
25 |
1500 |
550 |
190 |
400 |
8.5 |
10 |
ATQ15 |
15 |
17/20 |
22 |
40 |
2000 |
900 |
280 |
400 |
10 |
12 |
ATQ19 |
19 |
17/20 |
22 |
40 |
2000 |
900 |
280 |
420 |
10 |
13 |
ATQ28 |
28 |
22/26 |
32 |
40 |
2000 |
900 |
280 |
450 |
12.75 |
17 |
ATQ38 |
38 |
22/26 |
32 |
60 |
2700 |
1250 |
400 |
450 |
12.75 |
18 |
ATQ50 |
50 |
22/26 |
32 |
90 |
3300 |
1600 |
600 |
450 |
12.75 |
19 |
ATQ60 |
60 |
24/29 |
42 |
120 |
5000 |
2400 |
800 |
500 |
14.5 |
22 |
ATQ80 |
80 |
24/29 |
42 |
180 |
5800 |
2800 |
1200 |
850 |
14.5 |
23 |
ATQ100 |
100 |
24/29 |
42 |
200 |
8000 |
3000 |
1300 |
900 |
14.5 |
25 |
ATQ150 |
150 |
25/29 |
50 |
180 |
5800 |
2800 |
1200 |
850 |
45 |
33 |
ATQ200 |
200 |
25/29 |
50 |
200 |
8000 |
3000 |
1300 |
900 |
45 |
35 |
ATQ250 |
250 |
25/29 |
50 |
200 |
8000 |
3000 |
1300 |
900 |
45 |
35 |
|
TOP |
Standard
Specifications |
Housing & Cover
|
Aluminium, Anodized |
Enclosure |
Watertight IP67, Nema 4 and 6 |
Ambient Temp |
-30°C~+70°C |
Power Supply (60Hz/50Hz)
|
110/220VAC, 1 Phase
380/440 VAC, 3 Phase |
Control Power |
110/220 VAC, 1 Phase, 60/50Hz |
Torque Switches |
2 X SPDT for ATQ15 and above |
Limit Switches |
2XSPDT 15A |
Stall Protection |
Built-in Thermal Protection |
Travel Angle |
90°±5° |
Indicator |
Continuous Position Indicator |
Manual Override |
HAND/AUTO Declutching Mechanism |
Self Locking |
Provide by means of Worm Gearing |
End Stopper |
External Adjustable Screws |
Space Heater |
20W for Anti-Condensation |
Conduit Entries |
Two G3/4" |
Lubrication |
MoS2 Lithium Base Grease |
Materials |
Steel, Aluminium Alloy, Al Bronze |
External Coating |
Dry Power, Epoxy-Polyester Munsell No.FJ-002 |
|
Optional
Items |
ALS
|
Additional 2 X SPOT Auxiliary
Limit Switches |
EXT |
Travel Angle 120°, 135°, 180°,
270° |
LCB |
Local Control Box (1)Local/Remote Selector
Switch (2)Open/Stop/Close Selector Switch |
POT |
Potentiometer 1k Ohm |
CPT |
Current Position Transmitter Output: 4-20mA
DC |
PCM |
Proportional Control Module Input signal:
4-20mA, 1-5V DC Output signal: 4-20mA DC |
EXP |
Explosion & Water Proof Enclosure Exd
II BT4 IP67 |
|
|
TOP |
|
|
Type |
ATQ03 |
ATQ04 |
ATQ06 |
ATQ09 |
ATQ15 |
ATQ19 |
ATQ28 |
ATQ38 |
ATQ50 |
ATQ60 |
ATQ80 |
ATQ100 |
Flange
ISO5211 |
F05 |
F05 |
F07 |
F07 |
F07 |
F07 |
F10 |
F10 |
F10 |
F10 F12 |
F10 F12 |
F10 F12 |
F07 |
F07 |
— |
— |
F10 |
F10 |
F12 |
F12 |
F12 |
F14 |
F14 |
F14 |
C |
50 |
50 |
70 |
70 |
102 |
102 |
102 |
102 |
102 |
125 |
125 |
125 |
A |
M6 |
M6 |
M8 |
M8 |
M10 |
M10 |
M10 |
M10 |
M10 |
M12 |
M12 |
M12 |
B |
10 |
10 |
14 |
14 |
14 |
14 |
17 |
17 |
17 |
19 |
19 |
19 |
D (Max) |
14 |
14 |
22 |
22 |
22 |
22 |
32 |
32 |
32 |
42 |
42 |
42 |
E |
40 |
40 |
55 |
55 |
57 |
57 |
75 |
75 |
75 |
85 |
85 |
85 |
F |
25 |
25 |
35 |
35 |
35 |
35 |
42 |
42 |
42 |
50 |
50 |
50 |
G |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
H |
60 |
60 |
60 |
60 |
64 |
64 |
70 |
70 |
70 |
78 |
78 |
78 |
I |
133 |
133 |
133 |
133 |
154 |
154 |
174 |
174 |
174 |
191 |
191 |
191 |
J |
196 |
196 |
196 |
196 |
199 |
199 |
228 |
228 |
228 |
264 |
264 |
264 |
L |
102 |
102 |
102 |
102 |
125 |
125 |
145 |
145 |
145 |
175 |
175 |
175 |
O |
200 |
200 |
200 |
200 |
250 |
250 |
350 |
350 |
350 |
350 |
350 |
350 |
T |
75 |
75 |
75 |
75 |
85 |
85 |
100 |
100 |
100 |
115 |
115 |
115 |
X |
241 |
241 |
241 |
241 |
272 |
272 |
290 |
290 |
290 |
331 |
331 |
331 |
Y |
208 |
208 |
208 |
208 |
239 |
239 |
274 |
274 |
274 |
306 |
306 |
306 |
Z |
256 |
256 |
256 |
256 |
263 |
263 |
298 |
298 |
298 |
342 |
342 |
342 |
P |
72 |
72 |
72 |
72 |
72 |
72 |
72 |
72 |
72 |
72 |
72 |
72 |
q |
166 |
166 |
166 |
166 |
187 |
187 |
192 |
192 |
192 |
209 |
209 |
209 |
U |
170 |
170 |
170 |
170 |
170 |
170 |
170 |
170 |
170 |
170 |
170 |
170 |
|
|
TOP |
|
|
Type |
ATQ150 |
ATQ200 |
ATQ250 |
Flange |
F16 |
F16 |
F16 |
ISO5211 |
F14 |
F14 |
F14 |
C |
160 |
160 |
160 |
A |
M20 |
M20 |
M20 |
B |
30 |
30 |
30 |
D (Max) |
50 |
50 |
50 |
E |
95 |
95 |
95 |
F |
60 |
60 |
60 |
G |
4 |
4 |
4 |
H |
241 |
241 |
241 |
I |
191 |
191 |
191 |
J |
264 |
264 |
264 |
L |
210 |
210 |
210 |
O |
350 |
350 |
350 |
T |
132 |
132 |
132 |
X |
357 |
357 |
357 |
Y |
323 |
323 |
323 |
Z |
505 |
505 |
505 |
|
TOP |
Application |
» |
For quarter turn valves automation
used in heating & ventilation, air-conditioning,
water treatment works, power generation, petrochemical
plants,oil storage facilities, chemical plants,
effluent treatment works, pulp & paper mills
and shipbuilding industry. |
|
|